Interpreting Cable Test Results
The PASS icon will be on if the cable has all
pins properly connected per T568A/B. The
FAIL icon will be on if there is a short or split
pair. Neither icon will be on if there are opens
or miswires. The wiremap should be inspected
for these types of errors.
Definition of Errors (See failure example
drawings) The three classes of faults discussed
below are in order of severity. The severity has
to do with the ability of a more severe error
to mask lower severity errors. For example,
if there is a short in the cable; miswires and
split pairs may not be detected for the pairs
involved in the short fault.
Short – The pair has a low resistance
connection from one wire of the pair to the
other wire of the pair, or to any other wire in
the cable or the shield. A short in the TEST
mode is indicated by the FAIL icon being on
and flashing X’s in the appropriate pin position
of the second line of pin numbers, plus one or
more error message lines listing all the pins
shorted together. In the PRE-TEST mode, the
error messages are displayed.