JDSU TP607 Guide de l'utilisateur Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
5
one of the four tone sounds provided. The up
and down arrows scroll through the pairs and
pins that have signal on them. All pins not
being driven are held at tester ground.
Setup – The setup mode is provided to set
user-selectable options. The beep-on-pass can
be turned on or off (default is on). The pass
criteria can be set for shielded or unshielded
cables (default is unshielded). The length and
length constant can be set for meters or feet
(default is feet). If the length units are changed,
the tester converts the currently set length
constant to the new units on exit of setup. The
up and down arrow buttons scroll through the
set-able options. The SEL button changes the
current setting to the other option. On exit, the
mode screen first offers to return to the last
mode used before entering setup.
The LanRoamerPRO
monitors for voltage
being present on the RJ jack when off, in
TEST/PRE-TEST mode or in LENGTH mode.
The “VOLTAGE!!” message appears on the
screen and the beeper sounds continuously
until the voltage is removed.
Vue de la page 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 23 24

Commentaires sur ces manuels

Pas de commentaire